Flue gas dew point by fuel — and why it sets the saving

The rule: you can only cool flue gas as far as its dew point and acid dew point allow, and that limit comes from the fuel, not from the exchanger. Gas fuels reach 50 °C and condense (8.4–8.5% saving); 0.01% S diesel reaches 45 °C only with an AL-6XN bundle (5.9–6.8%); biomass must stay dry at 80 °C (4.9–5.7%).

Water dew point is set by hydrogen in the fuel

Every kilogram of hydrogen in the fuel becomes nine kilograms of water vapour. LPG is hydrogen-rich, so its flue gas carries about 9.8% water by mass and its dew point sits at 54.6 °C. Diesel oil carries less hydrogen and far more air per unit of energy, so its flue gas holds about 7.4% water and the dew point falls to roughly 47 °C. Biomass carries water from moisture as well as hydrogen, so the dew point is high, 55–60 °C, but the condensate is not clean.

Acid dew point is set by sulphur and chlorine

Sulphur in the fuel oxidises to SO2 and a small fraction to SO3, which with water forms sulphuric acid. Above roughly 0.01% S the acid dew point sits well above the water dew point and the cold end must respect it, or the exchanger corrodes. Chlorine in biomass does the same job with hydrochloric acid, and alkali metals add sticky deposits that keep a wet surface permanently fouled.

The four cases we build for

All four rows use the same boiler, the same steam duty and the same measurement method. The difference in the result comes entirely from the cold-end limit and the water content of the flue gas.

FuelWater dew pointCold endLatentFuel savingCold-end material
Natural gas / CNG55–57 °C50 °CYes8.4–8.5%SS 316L
LPG54.6 °C50 °CYes8.4–8.5% (measured)SS 316L
Diesel 0.01% S~47 °C45 °CYes, small5.9–6.8%AL-6XN
Biomass (wood chips, 30% moisture)55–60 °C80 °C (dry)No4.9–5.7%Chloride-tolerant, not 316L

Gas and LPG rows are measured; diesel and biomass are engineering cases dated 2026-11 using the same boiler, duty and measurement method.

How the limit is handled in practice

On gas fuels: no special measure beyond a drain and a bypass.

On 0.01% S diesel: the tube bundle is AL-6XN (UNS N08367), a super-austenitic stainless with about 6% molybdenum, which resists pitting in dilute sulphuric and chloride condensate where 316L would not. The package adds condensate neutralisation, a soot blower and corrosion coupons.

On biomass: the unit runs non-condensing at 80 °C with a soot blower; the recovered heat is sensible only, and a standard 316L bundle is not the right material for chloride-bearing deposits.

Related

Download the M&V reports Send project data