Answer: yes, diesel flue gas can be condensed. With an AL-6XN (UNS N08367) tube bundle the cold end goes to 45 °C and the recovery is 5.9–6.8% of fuel (540 kW on 10 t/h, 933 kW on 20 t/h). It needs condensate neutralisation, a soot blower and corrosion coupons; the standard 316L bundle is not specified for this duty.
Diesel carries sulphur. Even at 0.01% the flue gas contains SO2 and a small amount of SO3, which with water forms sulphuric acid. That acid condenses on a cold surface at a temperature well above the water dew point, so the cold end of the exchanger is a corrosion question before it is a thermodynamic one.
Diesel also carries less hydrogen per unit of energy than gas, so there is less water vapour in the flue gas (about 7.4% by mass) and less latent heat to win. The result is a lower percentage than gas, but a high money value because diesel costs far more per MMBtu.
316L resists dilute sulphuric acid at moderate chloride levels, but pitting risk rises where chlorides are present and where the surface cycles wet and dry. AL-6XN raises the pitting resistance substantially (about 6% molybdenum, PREn around 45) and is the material we specify when the cold end is taken below the acid dew point.
Cost effect: about +25% on the installed capital, which on a 20 t/h unit is the difference between USD 320,000 and USD 400,000. The payback still lands inside a year because the fuel bill is large.
Condensate drain with neutralisation to bring the discharge to a suitable pH; a soot blower, because oil firing leaves deposits that blunt the fin surface; and corrosion coupons in the condensate path so the material decision is checked in service rather than assumed.
The bypass diverter stays: it protects the cold end when the boiler load is too low to use the recovered heat.
Vendor documentation for flue-gas heat exchangers commonly holds sulphur-bearing oil flue at 130–150 °C, above the acid dew point. Condensing at 45 °C is therefore an engineering scope decision, declared in the contract, backed by the material selection and by the monitoring above — not a catalogue default.